CVE-2022-43452
Published Nov 17, 2022SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Vendor/product archive
82 CVEs tagged to deltaww / diaenergie — 39 Critical, 35 High, 8 Medium, 0 Low, 0 Unrated.
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploi…
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authe…
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker cou…
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API.
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have thi…
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts vi…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbit…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrar…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL quer…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegf. This allows an attacker to inject arbitrary SQL queries…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadREGbyID. This allows an attacker to inject arbitrary SQL quer…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queri…
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL…