CVE detail
CVE-2018-9080
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, by setting the Iomega cookie to a known value before logging into the NAS's web application, the NAS will not provide the user a new cookie value. This allows an attacker who knows the cookie's value to compromise the user's session.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 6.9 · diversity 5.0 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
1 source links · newest first
Experts discovered nine vulnerabilities affecting NAS devices that could be exploited by unauthenticated attackers to access protected content. Nine flaws affecting NAS devices could be exploited by unauthenticated attackers to access protected content. The vulnerabilities are traked as CVE-2018-9074, CVE-2018-9075, CVE-2018-9076, CVE-2018-9077, CVE-2018-9078, CVE-2018-9079, CVE-2018-9080, CVE-2018-9081 and CVE-2018-9082. According to Lenovo, the flaws affect 20 models of network attached storage (NAS) devices sold by the […]
newssecurityaffairs.comOct 3, 2018, 1:10 PM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2018-9082CVSS 8.8 · High
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the password changing functionality available to authenticated users does not require the user's…
- CVE-2018-9081CVSS 4.7 · Medium
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file name used for assets accessible through the Content Viewer application are vulnerable t…
- CVE-2018-9079CVSS 9.8 · Critical
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, adversaries can craft URLs to modify the Document Object Model (DOM) of the page. In addition, a…
- CVE-2018-9078CVSS 8.8 · High
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the Content Explorer application grants users the ability to upload files to shares and this ima…
- CVE-2026-62825CVSS 10.0 · Critical
Improper authentication in Azure Key Vault allows an unauthorized attacker to elevate privileges over a network.
- CVE-2026-56191CVSS 10.0 · Critical
Improper authentication in Microsoft Exchange Online allows an unauthorized attacker to perform tampering over a network.